Alloy-computer-products 16-PORT GIGABIT WEB SMART SWITCH GSS-16T2SFP Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Notebooky Alloy-computer-products 16-PORT GIGABIT WEB SMART SWITCH GSS-16T2SFP. Alloy Computer Products 16-PORT GIGABIT WEB SMART SWITCH GSS-16T2SFP User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - User’s Manual

ALLOY 16-Port Gigabit Web Smart Switch GSS-16T2SFP (16x 10/100/1000Mbps ports + 2 paired SFP Ports) User’s Manual Version: 1.03 February 8, 20

Strany 2

4 • 802.1Q VLAN • Maximal packet length up to 9216 bytes for jumbo frame applications • Broadcasting Suppression to avoid network problems • Trap

Strany 3 - Table of Contents

5 1-4. Overview of the GSS-16T2sfp Gigabit Web Smart Switch 1-4-1. User Interfaces on the Front Panel (Button, LEDs and Plugs) T

Strany 4

6 • LED Indicators LED Color Function System LED POWER Green Lit when +5V DC power is on and good 10/100/1000Ethernet coppers Port 1 to 16

Strany 5

7 1-5. Overview of the Optional SFP Modules With the GSS16T2SFP switch, copper ports 15 and 16 are paired with the SFP Fiber ports (LC); these ports

Strany 6

8 2. Installation 2-1. Starting the GSS16T2SFP Gigabit Web Smart Switch This section provides a quick start guide for: - Hardware and Cable

Strany 7 - About this user’s manual

9 • Copper Ports Cable Installation ⇒ The switch copper ports support MDI/MDI-X auto-crossover. This enables use of either straight-through or cros

Strany 8 - 1. Introduction

10 2-1-2-1. Cabling Requirements for TP Ports ⇒ For Fast Ethernet copper network connections  The Cable must be Cat. 5 or Cat. 5e with a maximum

Strany 9 - 1-3. Features

11 4. Operation of Web-based Management This chapter instructs you how to configure and manage the GSS16T2SFP Gigabit Web Smart Switch throu

Strany 10

12 Fig. 4-1 4-1. Web Management Home Overview After you have successfully logged into the switch the system status information is displayed as

Strany 11

13 Fig. 4-2

Strany 13

14 • The Basic Page Layout.  The switch graphic at the top section of the windows, displays the current status of both Copper TP and Fibre SFP po

Strany 14 - 2. Installation

15 4-2. Configuration 11 functions are including in the System Configuration group. Each of them will be described in detail in the following section

Strany 15 - 2-1-2. Cabling Requirements

16 4-2-1. System Configuration System configuration is one of the most important options in the switch. Without proper configuration, the network man

Strany 16

17 IP Address (RW): Configure the IP settings. Then, click <Apply> button to update. Default: 192.168.1.1 Subnet Mask (RW): Configure the Sub

Strany 17 - Web-based Management

18 4-2-2. Ports Configuration Function name: Port Configuration Function description: Port Configuration allows changing of the various port setting

Strany 18

19 4-2-3. VLAN Mode Configuration The switch supports Port-based VLAN and Tag-based VLAN (802.1q). 16 active VLANs can be support with VLAN ID’s fro

Strany 19 - Fig. 4-2

20 Metro Mode: Metro Mode is a quick configuration VLAN option designed for Metro WAN deployment. It uses Port-based VLAN and creates 14 or 15 Port-

Strany 20 - The Basic Page Layout

21 Up-link Port: This feature is only enabled when the metro mode is selected. Option 15: All ports are assigned a unique VLAN with Port 15. Port

Strany 21 - 4-2. Configuration

22 4-2-4. VLAN Group Configuration Function name: VLAN Group Configuration Function description: In port-based VLAN mode, this will display the ID –

Strany 22 - 4-2-1. System Configuration

23 Fig. 4-7 Add Group: Create a new port-based VLAN or tag-based VLAN, depending on the VLAN mode selected. Fig. 4-8

Strany 23

Table of Contents CAUTION----------------------------------------------------------------------------------------------------------III ELECTRONIC

Strany 24 - 4-2-2. Ports Configuration

24 Delete Group: Select the check box (;) beside the ID, to delete a group. Then press the <Delete Group> button to delete the group. Fig. 4-

Strany 25

25 4-2-5. PVID Configuration Function name: PVID Configuration Function description: From within this menu users can assign a VID number for each po

Strany 26 - Fig. 4-5

26 Untag State: If this is enabled and the Untag VID matches the VID of the packet, then the tag would be removed. If enabled without a match, no op

Strany 27 - Fig. 4-6

27 4-2-6. Aggregation Configuration The Aggregation (Port Trunking) Configuration is used to configure Link Aggregation. You can bundle more than one

Strany 28

28 4-2-7. Mirror Configuration Function name: Mirror Configuration Function description: Mirror Configuration is used to monitor the traffic on the

Strany 29 - Fig. 4-8

29 4-2-8. Quality of Service Configuration The switch offers powerful QoS functions including: VLAN tagged priority for 8 levels, TOS field IP header

Strany 30 - Fig. 4-9

30 Fig. 4-14 Parameter description: Quality of Service (QoS) Vlan Tag Configuration: Used for setting up QoS based on Vlan tags. Port: Select the

Strany 31 - 4-2-5. PVID Configuration

31 Function name: IP ToS Classification Function description: Within the Layer 3 network framework is a TOS field for IP headers. The GS-16T2SFP can

Strany 32 - Fig. 4-10

32 Function name: IP TCP/UDP Port Classification Function description: In L4 QoS Configuration you can prioritize packets based on the application typ

Strany 33 - Fig. 4-11

33 Advanced Mode: The Advanced Mode allows you to further customize the initial simple configuration defaults with your own TCP/UDP port definitions.

Strany 34 - ;) under the

ii 4-3. MONITORING --------------------------------------------------------------------------------------------- 40 4-3-1. Statistics Overview-----

Strany 35 - Fig. 4-13

34 Fig. 4-16 Advanced Mode Fig. 4-17 Simple Mode Simple Mode: Toggle the <Simple> / <Advanced> button to switch between modes and t

Strany 36 - Fig. 4-14

35 Function name: IP Diffserv Classification Function description: IP Diffserve Classification supports up-to 64 (0~63) Traffic Classifications base

Strany 37 - Fig. 4-15

36 4-2-9. Bandwidth Management Function name: Bandwidth Management Function description: The Bandwidth Management function is used to set Ingress an

Strany 38

37 All Traffic for Egress Rate Limiting: Define the rate for outgoing traffic on the selected port. Packet transmission will be delayed if the rate

Strany 39

38 4-2-10. Trap Event Configuration Function name: Trap Event Configuration Function description: The Trap Event Configuration enables the GSS-16T2S

Strany 40 - Fig. 4-17

39 4-2-11. Max. Packet Length Function name: Max. Packet Length Function description: The switch is capable of dealing with 9k Jumbo Frames. Jumbo f

Strany 41 - Fig. 4-18

40 4-3. Monitoring There are two functions contained in the monitoring section of the management. 4-3-1. Statistics Overview The Statistics

Strany 42 - 4-2-9. Bandwidth Management

41 Fig. 4-22 4-3-2. Detailed Statistics Function name: Detailed Statistics Function description: Displays detailed counters for a speci

Strany 43

42 TX Octets: Total transmitted bytes. Tx High Priority Packets: Number of Tx packets classified as high priority. Tx Low Priority Packets: Number of

Strany 44 - Fig. 4-20

43 Tx 1024-Bytes: Number of 1024-max_length-byte frames (includes non valid packets) transmitted. Rx CRC/Alignment: Number of Alignment errors and CR

Strany 45 - 4-2-11. Max. Packet Length

iii Caution Electronic Circuit devices are sensitive to static electricity. Dry weather conditions or walking across a carpeted floor may cause

Strany 46 - 4-3. Monitoring

44 4-4. Maintenance There are four functions contained in the maintenance section. 4-4-1. Status 8 sections are reported on in the sw

Strany 47 - 4-3-2. Detailed Statistics

45 4-4-1-1.Switch Status Fig. 4-24 Function name: Switch Status Function Description: Display the status information of this switch. Parameter

Strany 48

46 MAC Address: Display the Ethernet MAC address of the switch. System Name: Display the model of the switch. Auto Logout Timer: Display the settin

Strany 49 - Fig. 4-23

47 4-4-1-2. TP / Fiber Ports Status Function name: TP/Fiber Ports Status Function description: TP/Fiber Port Status, displays a summary of the port

Strany 50 - 4-4-1. Status

48 4-4-1-3. Aggregation Function name: Aggregation Status Function description: Display the current setup of Aggregation/Trunking. Parameter descri

Strany 51 - Fig. 4-24

49 4-4-1-4. VLAN Function name: VLAN Status Function description: Display the status the switch VLAN mode and VLAN group settings. Parameter descri

Strany 52

50 Fig. 4-29 Metro mode VLAN

Strany 53 - Fig. 4-25

51 4-4-1-5. Mirror Function name: Mirror Status Function description: Mirror Status displays the current mirror configuration. Parameter description

Strany 54 -

52 4-4-1-6. Trap Event Function name: Trap Event Status Function description: Display the switch’s trap information and trap events. Parameter desc

Strany 55 - Fig. 4-27 Tag-based VLAN

53 4-4-1-7. Maximum Packet Length Function name: Max. Packet Length Status Function description: Display the per port setting for maximum packet len

Strany 57 - Fig. 4-30

54 4-4-2. Warm Restart The Web management interface offers a Warm Restart option. This simply reboots the switch with the current switch settings int

Strany 58 - Fig. 4-31

55 4-4-3. Factory Default Function name: Factory Default Function description: Factory Default function will reset the default setting and replace t

Strany 59 - Fig. 4-32

56 4-4-4. Logout The GSS-16T2SFP support an auto logout from the web interface, but there is also a manual logout function. If you need to release co

Strany 60 - 4-4-2. Warm Restart

57 5. Maintenance 5-1. Resolving No Link Condition The possible causes for a not receiving link are: z The attached device is not powered on z Th

Strany 61 - 4-4-3. Factory Default

58 Appendix A Technical Specifications Features • 14 (10/100/1000Mbps) Gigabit Ethernet (TP) switching ports compliant with IEEE802.3, 802.3u, 80

Strany 62 - 4-4-4. Logout

59 Hardware Specifications  Standard Compliance: IEEE802.3/802.3ab / 802.3z / 802.3u / 802.3x  Network Interface: Configuration Mode Conne

Strany 63 - 5. Maintenance

60  Diagnostic LED: System LED : Power Per Port LED: 10/100/1000M TP Port 1 to 16 : LINK/ACT, 10/100/1000Mbps 1000M SFP

Strany 64 - Technical Specifications

About this user’s manual This user’s manual will guide you on how to install, configure and monitor the 16 port Gigabit Web Smart Switch through t

Strany 65 - Hardware Specifications

2 1. Introduction 1-1. Overview of the 16 Gigabit Web Smart Switch The 16-port Gigabit Web Smart Switch meets all IEEE 802.3/u/x/z Gigabit, Fast Ethe

Strany 66

3 1-2. Checklist Before you start installing the switch, verify that the package contains the following:  The GSS-16T2SFP Gigabit Web Smart Switch